Variable Frequency Drives

We are a leading Distributor / Channel Partner of l&t cx2000 vfd, 0.1 kw to 11 kw, 1/3 phase from Indore, India.

L&T Cx2000 VFD, 0.1 kW to 11 kW, 1/3 Phase

₹ 10,500 /Piece Get Latest Price

Product Brochure
Model Name/NumberCX2000
Motor Power0.1 kW to 11 kW
Input Voltage200-480 VAC (-15% ~ +10%)
Input Phase1/3 Phase
DisplayDigital
IP RatingIP20
BrandL&T
Input Frequency50/60Hz (-5/+5%)
Starting Torque150% at 3 Hz in V/F
Accel/Decel Time0.0 to 6000 Sec
Output Frequency Resolution0.01Hz
Output Frequency0 to 400Hz (Sensorless 0 to 120Hz)
Control MethodV/F control, sensorless vector control, slip compensation

Compact, lightweight, easy to install, operate and service – the Cx2000 is perfectly suited for conveyors, pumps, fans and textile machinery. It handles loads up to 11 kW, and is engineered to keep your machine operating at optimum efficiency, even in the hot, humid and dusty conditions that characterise India's industrial environment.

Range:

  • Single Phase 230V - 0.1 to 2.2kW
  • Three Phase 230V - 0.2 to 11kW
  • Three Phase 415V - 0.75 to 11kW

Enclosures:
  • IP20

Features:

  • V/F Control, Sensorless Vector Control, Slip Compensation
  • Starting Torque 150% at 3 Hz
  • Built-in Potentiometer
  • Conformal Coated PCB
  • Built-in RS485 Modbus
  • RPM Display
  • Draw Mode
  • Brake Control
  • Auto Tuning
  • Built-in PID
  • 2nd Motor Operation
  • Built-in Safety circuit
  • Built-in Braking Chopper up to 11kW

Dual rating operation:
  • Designed to be used for heavy and normal duty applications.

Overload capacity
  • Heavy duty operation: 150% of rated current for 60 sec
  • Normal duty operation: 110% of rated current for 60 sec

Built-in Potentiometer:
  • Possible to add reference from keypad and external signal Provides external potentiometer for easier frequency control

Built-in PID:
  • Cx2000 has built-in PID which saves use of external PID

2nd Motor Operation:
  • Single AC Drive can maintain 2 motor parameters connected to 2 different loads with different Accel / Deccl parameter setting
  • For isolated operation of motors one VFD can be used in place of 2

Easy Maintenance:
  • Tool-less replacement of Cooling Fan.

Built-in Brake Chopper:
  • Built-in brake chopper which saves panel space.

Model No.:

  • LTVF-C10001BAA

  • LTVF-C10002BAA

  • LTVF-C10003BAA

  • LTVF-C10005BAA

  • LTVF-C10008BAA

  • LTVF-C10011BAA

  • LTVF-C20001BAA

  • LTVF-C20002BAA

  • LTVF-C20003BAA

  • LTVF-C20006BAA

  • LTVF-C20010BAA

  • LTVF-C20012BAA

  • LTVF-C20018BAA

  • LTVF-C20030BAA

  • LTVF-C20040BAA

  • LTVF-C20010BAA

  • LTVF-C40002BAA

  • LTVF-C40003BAA

  • LTVF-C40005BAA

  • LTVF-C40007BAA

  • LTVF-C40010BAA

  • LTVF-C40016BAA

X

Contact Us

Sudarshan Chitale (CEO)
Emechem
17, Pologround Industrial Area, Near Marimata Square
Indore - 452007, Madhya Pradesh, India

Get Directions
Send Email
Share: